GENERAL ELECTRIC Lighting Contactor

General Electric lighting contactors are ideal for controlling high-intensity lighting systems. These contactors enable efficient management of lighting circuits, allowing for remote operation and ...Read More

Filter
Full Load Amps: 30 , Full Load Amps-Inductive: 30 , Full Load Amps-Resistive: 30 , HP @ 1 Phase - 120V: 1 , HP @ 1 Phase - 230V: 2 , HP @ 1 Phase - 240V: 2 , HP @ 3 Phase - 208V: 3 , HP @ 3 Phase - 230V: 5 , HP @ 3 Phase - 240V: 5 , HP @ 3 Phase - 480V: 10 , HP @ 3 Phase - 575V: 15
StyleModelNumber of PolesCoil VoltsContactor TypeWidthDepthEnclosure TypeHeightHzPrice (inc. GST)
A
CR463L20AJA
2120 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 567.20
B
CR463M20CJA
2115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,045.52
B
CR463M20DNA
2277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,032.36
C
CR463M20DNA10A0
2277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,208.91
D
CR463M20NJA
2115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,070.59
E
CR463M20NJA10A0
2115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,139.43
D
CR463M20PNA
2277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,070.59
E
CR463M20PNA10A0
2277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,250.86
C
CR463M20CJA10A0
2115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,101.20
F
CR463L20AJA10A0
2120 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 682.84
F
CR463L20ANA10A0
2240/277 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 682.84
A
CR463L20ANA
2240/277 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 567.20
G
CR463M40CJA10A0
4115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,557.33
H
CR463M40CJA
4115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,463.62
I
CR463M40NJA
4115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,387.97
J
CR463M40NJA10A0
4115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,599.29
I
CR463M40PNA
4277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,387.97
J
CR463M40PNA10A0
4277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,599.29
H
CR463M40DNA
4277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,481.78
G
CR463M40DNA10A0
4277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,557.33
K
CR463L40AJA10A0
4120 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 947.30
L
CR463L40AJA
4120 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 872.72
L
CR463L40ANA
4240/277 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 872.72
K
CR463L40ANA10A0
4240/277 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 947.30
M
CR463M60PNA
6277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,872.11
N
CR463L60AJA10A0
6120 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 1,355.74
O
CR463M60PNA10A0
6277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,073.66
M
CR463M60NJA
6115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,705.36
P
CR463M60DNA10A0
6277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,031.66
P
CR463M60CJA10A0
6115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 1,850.65
Q
CR463M60CJA
6115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,663.63
R
CR463L60AJA
6120 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 1,170.30
Q
CR463M60DNA
6277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 1,830.16
N
CR463L60ANA10A0
6240/277 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 1,355.74
R
CR463L60ANA
6240/277 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 1,170.30
S
CR463M80CJA
8115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,004.21
T
CR463M80PNA10A0
8277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,422.00
U
CR463M80PNA
8277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,220.49
T
CR463M80NJA10A0
8115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,422.00
U
CR463M80NJA
8115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,220.49
V
CR463M80DNA10A0
8277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,380.01
S
CR463M80DNA
8277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,178.53
V
CR463M80CJA10A0
8115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,167.97
W
CR463L80AJA10A0
8120 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 1,656.41
X
CR463L80AJA
8120 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 1,438.34
W
CR463L80ANA10A0
8240/277 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 1,656.41
X
CR463L80ANA
8240/277 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 1,438.34
Y
CR463MB0PNA10A0
10277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,770.43
Z
CR463MB0PNA
10277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,568.94
Y
CR463MB0NJA10A0
10115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,770.43
Z
CR463MB0NJA
10115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,568.94
A1
CR463MB0DNA10A0
10277 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,728.45
B1
CR463MB0DNA
10277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,526.98
A1
CR463MB0CJA10A0
10115/120 VACMechanically Held4.2ft.3.9"NEMA 17.4"60 SGD 2,728.45
C1
CR463LB0ANA10A0
10240/277 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 2,026.71
B1
CR463MB0CJA
10115/120 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,324.70
D1
CR463LB0AJA
10120 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 1,741.55
C1
CR463LB0AJA10A0
10120 VACElectrically Held4.2ft.3.9"NEMA 17.4"50/60 SGD 2,026.71
D1
CR463LB0ANA
10240/277 VACElectrically Held4.2ft.3.9"Open7.4"50/60 SGD 1,741.55
E1
CR463MD0NJA10A0
12115/120 VACMechanically Held10ft.4.63"NEMA 110ft.60 SGD 3,118.84
F1
CR463MD0DNA
12277 VACMechanically Held4.2ft.3.9"Open7.4"60 SGD 2,619.22
12

Lighting Contactor

General Electric CR460 Series lighting contactors are widely used for controlling the flow of power supply in lighting circuits and feature a compact design with a NEMA-rated enclosure (on selected models) to prevent the ingress of contaminants in exposed installations. These electrical / mechanical lighting contactors further come equipped with power terminals designed to provide protection to fingers and back of the hand against electrical shocks and 12 poles for simultaneously handling multiple devices. Their power poles are easily installable & can change from NO to NC (vice versa) configuration by simply unlatching and repositioning the lever. The quick snap-in auxiliary contacts of these relay switches facilitate both normally open and normally closed configurations, when installed on the left and right side of the contactor, respectively.

Working Mechanism

  • These lighting contactors are electrical devices designed to control the operation of lighting circuits in buildings and industrial settings.
  • They are made of a coil that, when energised, creates a magnetic field, pulling down a set of contacts to close the electrical circuit.
  • These contacts are responsible for connecting / disconnecting the power supply to the lighting fixtures.
  • The contactor also includes an auxiliary contact set for signalling or control purposes.

Features

  • These electrical / mechanical lighting contactors are equipped with power terminals designed to protect fingers and the back of the hand against electrical shocks and 12 poles for simultaneously handling multiple devices.
  • They have an open / NEMA 1 enclosure to provide limited protection against dust and accidental contact with live electrical parts.
  • These GE lighting contactors are designed for reliable switching of lighting circuits, ensuring that lights turn on and off as intended.
  • They offer snap-in auxiliary contacts to extend the functionality of electrical switches, contactors or circuit breakers by easily attaching within compatible mounting locations and enabling signal transmission.

Frequently Asked Questions

What are the main components of a GE lighting contactor?

GE lighting contactor consists of a coil, a set of contacts (usually NO - normally open), an auxiliary contact set (for signalling or control purposes) and a housing to protect the components.

How to maintain these GE lighting contactors?

  • Regularly inspect the contactor for wear and loose connections.
  • Clean contact surfaces to remove dust and debris.
  • Tighten all electrical connections to ensure security.
  • Check the coil for damage and verify control circuit protection.
  • Replace damaged or worn components with genuine parts.
  • Maintain records of maintenance activities for reference.
  • Adhere to safety precautions and use appropriate PPE during maintenance tasks.

Can GE lighting contactors be integrated into building automation systems?

Yes, GE lighting contactors can often be integrated into building management and automation systems, allowing for centralised control & monitoring of lighting.

How do I install these GE lighting contractors?

  • Turn off power to the circuit before beginning installation.
  • Securely mount the contactor in a well-ventilated location.
  • Wire the incoming power supply to line-side terminals as per the diagram.
  • Connect lighting fixtures or devices to the load-side terminals.
  • Wire the control circuit to the contactor's coil with proper protection.
  • Ensure the contactor is grounded for safety.

We are here to help!