A Disc Material: Teflon , Material: Brass , Pressure Range: 1 - 400 Psi , Temperature Range: -250 - 350 Deg F
Features
- Kingston 205 Series horizontal anti-hammering check valves feature a dashpot piston for lowering the hammering effect in compressed air applications.
- These dashpot check valves facilitate easy removal of rust and scale residues.
- They are equipped with Teflon discs to withstand temperatures ranging from -250 to 350 degrees F.
- These dashpot check valves can be operated at a maximum operating pressure of 400 PSIG.
- They come with a spring made of stainless steel for corrosion resistance.
Frequently Asked Questions
How to maintain Kingston 205 Series horizontal anti-hammering check valves?
- Inspect the check valves when working.
- Disassemble the valves if damaged or worn and go through the Viton O-ring and valve body.
- Lubricate the Viton O-ring with silicone lubricant and reassemble it into a single piece.
How to install these horizontal dashpot check valves?
- Horizontal check valves are installed in horizontal piping.
- Place the check valve at the lowest elevation in the plumbing system possible so that the weight of the water column can help seal it for excellent sealing.
- The recommended minimum height of a water column is 18 inches for installation.