Flat Rate Shipping at 19.99 + GSTSGD 19.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates.
SGD 1,026.25 /unit (inc. GST)
Add To Cart
Request a Quote
Payment Methods
Delivery Partners
Product Specifications:
Item
Variable Frequency Drive
Accepts Input Control Signal
0-10VDC, 4-20mA
Adjustable Acceleration Time
0.01 to 6000 sec.
Adjustable Deceleration Time
0.01 to 6000 sec.
Depth
5.63"
Digital Readout
Yes
Display Type
LED
Displays
Drive Voltage
Dynamic Braking
Internal Brake Chopper Circuit
Enclosure
NEMA 1
Height
5.51"
Input Frequency
50/60Hz
Input Phase AC
3
Input Voltage
460 VAC
Key Pad Lockout
Yes
Max. HP
1.5
Max. Output Amps
3.4
Output Frequency Range
0 to 400 Hz
Output Voltage
460 VAC
Protection
IP20
Start/Stop Control
Programmable
Starting Torque
150%
Torque @ 1 Hz
150%
Width
4.33"
Shipping Info:
Ship weight (kg)
1.87
Product Details:
Designed to ramp down the frequency or voltage and provide protection against motor overload conditions, as well as adjust the motor speed
Features a sensor-less flux torque vector control mechanism for automatically calculating the motor performance
Dual-channel RS485 communication port utilising half-duplex bus configuration for transmitting and receiving data from each end
Includes a keypad with an LED screen displaying the duration, number of operational activities, the status of input / output settings and alarms
Meets UL, cUL, 508C, NO14, CE RoHS, GOST-R and KC standards
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure
Over breaking, Overvoltage, Under voltage, Motor Thermal Overload, Drive Thermal Overload, Phase to Phase or Phase to Ground Short Circuit, Phase Failure