Product Specifications:

ItemWater Regulating Valve
ApplicationHead Pressure Control with Non-Corrosive Refrigerants
ConnectionFlange
Connection Size1 1/2"
Connection TypeFlange
Design Pressure (PSIG)320 psig
Port1-1/2"
Port Size1 1/2"
Repair KitSTT17A-610R
Replacement CartridgeSEP91A-603R
Set Points70 to 260
Type2 Way
Use WithNon Corrosive Refrigerants

Shipping Info:

Ship weight (kg) 6.48
Ship height (cm)17.78
Ship length (cm)38.1
Ship width (cm)20.32
HS code8481809050
Country of OriginMX

Product Details:

Johnson Controls V46AR-1C water regulating valve is a 2 way pressure-actuated valve used on open or closed refrigeration systems to regulate the flow of head pressure while transferring water to a water-cooled condenser.

Working Mechanism:

  • Johnson Controls V46AR-1C valve employs a hydraulic actuator, composed of a diaphragm assembly and a control chamber. The diaphragm assembly is responsive to shifts in pressure and it reacts to alterations in the control signal.
  • The control signal, often presented as pressure, is fine-tuned according to the desired water flow rate. As the control signal shifts, it influences the pressure on one side of the diaphragm assembly.
  • Changes in pressure on one side of the diaphragm prompt its movement. This movement subsequently adjusts the valve's aperture, governing the water flow rate.

Frequently Asked Questions:

Q. What is the difference between a regulating valve and a reducing valve?

A. The contrast lies in the intended medium and purpose of these valves. A regulating valve is crafted to manage pressure within a gas medium, whereas a pressure-reducing valve is constructed to function with liquids. Both valves are typically in an open state, as evidenced by the arrow intersecting both the inlet and outlet ports.

Q. What are the three types of control valves?

A.

  • Manifold Valves
  • Ball Valves
  • Double Block and Bleed Valves

Q. How do I increase the water pressure in my tank with this water controlling valve?

A.

  • To increase pressure, a pressure pump connected to the discharge line can be beneficial. This pump will elevate both water pressure and the volume of water flowing from an overhead tank.
  • Ensure that the valve is in the correct position on the discharge line. A properly positioned check valve prevents water from flowing back into the tank, maintaining pressure.
  • The elevation of your overhead tank impacts the pressure. A higher tank placement can generate more pressure due to gravitational force.
  • Blockages or debris in the pipeline can hinder water flow and pressure. Regularly inspect and clean pipes, filters and valves to prevent obstruction.
  • Adjust the pressure pump settings to achieve the desired pressure level. However, be cautious not to exceed the system's design limits.

Q. How do I choose a control valve size?

A. Selecting the appropriate size for a control valve involves considering its operational range. Opt for a valve size that enables operation between 60 and 80 percent open during peak flow rates. Additionally, aim to avoid selecting a size that falls significantly below 20 percent open during minimum flow rates, whenever feasible.

Documentation:

Product Variants

ProductModelConnectionConnection SizePortReplacement CartridgePrice
JOHNSON CONTROLS V46AA-1C Pressure Actuated Water Regulating Valve, 3/8 Inch NPT, Threaded | AD3MWY 40G447
V46AA-1CNPT3/8"3/8"SEP91A-600R SGD 400.84
JOHNSON CONTROLS V46AB-1C Pressure Actuated Water Regulating Valve, 1/2 Inch NPT, Threaded | AD3MWZ 40G448
V46AB-1CNPT1/2"1/2"SEP91A-602R SGD 438.08
JOHNSON CONTROLS V46AC-1C Pressure Actuated Water Regulating Valve, 3/4 Inch NPT, Threaded | AD3MXA 40G449
V46AC-1CNPT3/4"3/4"SEP91A-601R SGD 481.27
JOHNSON CONTROLS V46AD-1C Pressure Actuated Water Regulating Valve, 1 Inch NPT, Threaded | AD3MXB 40G450
V46AD-1CNPT1"1"SEP91A-603R SGD 1,004.02
JOHNSON CONTROLS V46AE-1C Pressure Actuated Water Regulating Valve, 1-1/4 Inch NPT, Threaded | AD3MXC 40G451
V46AE-1CNPT1-1/4"1-1/4"SEP91A-603R SGD 1,183.82
JOHNSON CONTROLS V46AS-2C Pressure Actuated Water Regulating Valve, 2 Inch NPT, 4 Hole ASME Flange | AD3MXE 40G453
V46AS-2CFlange2"2"SEP81A-601R SGD 1,906.17
JOHNSON CONTROLS V46AT-2C Pressure Actuated Water Regulating Valve, 1/2 Inch NPT, 4 Hole ASME Flange | AD3MXF 40G454
V46AT-2CFlange2-1/2"2-1/2"SEP81A-601R SGD 2,767.08

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 09:00 until 17:00.

JOHNSON CONTROLS V46AR-1C Pressure Actuated Water Regulating Valve, 1-1/2 Inch NPT, 4 Hole ASME Flange
SGD 1,457.80 /unit (inc. GST)