PARKER D1VW001CNJW Hydraulic Directional Control Valve, Nitrile Seal, 24VDC | AC2WKU 2NMV2

PARKER D1VW001CNJW Hydraulic Directional Control Valve, Nitrile Seal, 24VDC

Item: AC2WKU Model: D1VW001CNJWCross Ref: 2NMV2
In Stock
Shipping to

Get it by May 3, Friday

Flat Rate Shipping at 19.99 + GST SGD 19.99 flat shipping is applicable on orders with an aggregate weight less than 10kg. Orders exceeding 10kg will be charged default shipping rates.

SGD 632.41 /unit (inc. GST)
Add To Cart
Request a Quote

Payment Methods

Delivery Partners

Product Specifications:

ItemControl Valve
Actuation TypeSolenoid
Coil Volts24 DC
GPM @ 3000 PSI20
Height1.97"
Input Voltage24 VDC
Length9.2"
Max. Flow Rate80 L/min
Max. Pressure5000 psi
Max. Tank Pressure (PSI)3000
Number of Positions3
Number of Ways4
Seal MaterialNBR
Seal TypeNitrile O-Ring
SizeCETOP-03
Spool TypeClosed
TypeSolenoid Operated
Width1.81"

Shipping Info:

Ship weight (kg) 2.23
Ship height (cm)6.1
Ship length (cm)28.45
Ship width (cm)11.43
HS code8481200020
Country of OriginUS

Product Details:

Parker D1VW001CNJW hydraulic valve is designed for controlling liquid flow in hydraulic & fluid power pneumatic systems. It also starts or stops the flow of liquid.

Working Mechanism:

  • Directional control valves (DCV) maintain fluid in a standby condition, preventing it from flowing from inside the system until it is required to move and fulfil its intended purpose.
  • When activated, directional control valves change into action, accomplish the task and shift back into neutral.
  • The valve is connected using separate wires for control.

Features:

  • Parker D1VW001CNJW hydraulic directional control valve has DC surge suppression mechanism for suppressing the external voltage spikes & proportional spools for controlling pressures up to 5000 psi.
  • It comes with a 4-way solenoid valve to control the flow of fluids in various directions.
  • This unit features waterproof & explosion-proof construction to ensure protection against harsh industrial conditions.
  • The model has a seal made of nitrile O-ring (NBR) to resist crude oil, petroleum oils, abrasion, water, propane and gasoline.
  • It allows spring return actuation to deliver power using spring force, providing flow ratings up to 20 GPM.

Compatible Accessories:

Standards and Approvals:

  • RoHS
  • CSA
  • ISO
  • NFPA

Frequently Asked Questions:

Q. What are the operating instructions of this DCV?

A.

  • The user must utilise a proper control system to operate the DCV valve.
  • The seal & connectors may be impaired and loosen if the screw connections are not tightened.
  • The valve and the electronic control system may malfunction due to short circuits between the wires, shoddy construction or improper shielding attachment.
  • As the solenoid heats, the current decreases. As long as the desired voltage is maintained at the valve, the decreased current has no impact on how the valve operates.
  • To manually activate the solenoid in an emergency, a proper instrument should be utilised.
  • It is advised to flush long pipes at large central pressurised oil stations in particular by cutting the pressure and return lines as it stops dirt from being transported to the valve during installation.
  • If the product has to be stored temporarily, it must be shielded from debris, weather and damage.

Q. How to vent a hydraulic system?

A.

  • When first commissioning, following an oil change, or after opening lines or valves, the hydraulic system has to be vented.
  • The highest point of the pipe network is where venting occurs.
  • To let air and a tiny bit of oil out, slightly loosen the vent screw.
  • Tighten the screw once more after the escaping oil is no longer foaming.
  • After that, do each function sequentially while using the lowest feasible pressure and no-load settings.
  • Now vent the system again.
  • Ensure that any oil (that escapes) is gathered and properly disposed of.

Q. How can leaking plugs affect the valve's performance?

A. Leaking plugs can cause a malfunction. Because of this, the plugs must be examined for leakage at the scheduled maintenance interval. It is necessary to send the valve back to the manufacturer for repair since leaking plugs might pose a safety risk.

Q. What happens in case of a power failure?

A. The valve piston returns to the spring centred starting position during a power outage. When using the system or machine, you must determine whether this poses any risks.

Q. How to install a DCV?

A.

  • Ensure that the outer O-rings are complete and intact before installation.
  • Damaged parts of O-rings must not be installed as they may impair the function of the valve.
  • Installation and lifting equipment should be used for installation, if necessary.
  • After securing the valve in place, tighten all nuts evenly and diagonally over the course of multiple passes, according to the manufacturer's recommended torque.
  • Check the sealing surface for leaks if the valve is pressurised for the first time.

Product Variants

ProductModelGPM @ 3000 PSIPrice
PARKER D1VW004CNJW Directional Control Valve, Nitrile O-Ring, Solenoid Operated | AC2WKV 2NMV3
D1VW004CNJW18.5 SGD 725.65

Contact us

Contact your account manager right away to get personal advice.
We're available Monday through Friday, from 09:00 until 17:00.

PARKER D1VW001CNJW Hydraulic Directional Control Valve, Nitrile Seal, 24VDC
SGD 632.41 /unit (inc. GST)