| Item | Circuit Breaker |
|---|---|
| Ac Voltage Rating | 525V AC |
| Ambient Air Temp. For Operation | -13°F to +158°F |
| Ambient Air Temp. For Storage | -58°F to +185°F |
| Amps | 20A |
| Awg Gauge | 6 AWG to 2/0 AWG, 14 AWG to 3/0 AWG |
| Breaking Capacity | 65 kA 208Y/120V AC 50/60 Hz UL 489, 65 kA 240V AC 50/60 Hz UL 489, 35 kA 480/277V AC 50/60 Hz UL 489, 35 kA 480V AC 50/60 Hz UL 489, 20 kA 250V DC UL 489, 20 kA 600Y/347V AC 50/60 Hz UL 489 |
| Breaking Capacity Code | G |
| Circuit Breaker Actuator | Toggle |
| Circuit Breaker Application | HACR Rated |
| Circuit Breaker Mounting Style | Unit Mount |
| Circuit Breaker Type | Standard |
| Color | Gray |
| Component Type | Circuit Breaker |
| Connection Pitch | 1.06" |
| Continuous Amps Rating | 80% |
| Control Type | Toggle |
| Dc Voltage Rating | Not Rated |
| Depth | 3.15" |
| Device Application | Distribution |
| Electrical Connection | Everlink Lug, Line, Load |
| Electrical Durability | 10000 Cycles |
| For Use With | Electrical Distribution Equipment, Industrial Control Panels |
| Frame Size | 125A, BG |
| Frame Type | BGL |
| Height | 5.39" |
| Ik Degree Of Protection | IK07 |
| Instantaneous Trip | Fixed |
| Ip Degree Of Protection | IP40 |
| Line Rated Amps | 20A |
| Local Signalling | Presence Of Auxiliary Contacts Flag Green |
| Max. Air Rating | 100 kA At 240V AC |
| Max. Operating Temp. | 158°F |
| Maximum Wire Size | 2 AWG, 3 AWG |
|---|---|
| Mechanical Durability | 20000 Cycles |
| Min. Operating Temp. | -13°F |
| Minimum Wire Size | 14 AWG, 6 AWG |
| Mounting Mode | Clip On 35 mm x 15 mm Symmetrical Din Rail, By Screws Plate |
| Network Frequency | 50/60 Hz |
| No. Of 9 Mm Pitches | 9 |
| No. Of Poles | 3 |
| Number Of Poles | 3 |
| Number Of Slots | 3 |
| Operating Altitude | 0 ft. to 6561.68 ft. Without Derating, 5000m With Derating |
| Phase | Three |
| Phase Connection | ABC |
| Pollution Degree | 3 IEC 60947-1 |
| Power Wire Stripping Length | 0.8" |
| Quality Labels | ce.png |
| Quantity Per Set | Set of 1 |
| Rated Impulse Withstand Voltage | 8 kV |
| Rated Insulation Voltage | 800V |
| Rated Operational Voltage | 525V |
| Rated Service Breaking Capacity | 65 kA @ 220-240V AC @ 50/60 Hz, 18 kA @ 500-525V AC @ 50/60 Hz, 35 kA @ 380-415V AC @ 50/60 Hz, 35 kA @ 440V AC @ 50/60 Hz |
| Returnability | Yes |
| Suitability For Isolation | Yes, IEC 60947-2 |
| Terminal Connection | Everlink Lug Both Ends |
| Tightening Torque | 44.3 lbf.in. @ 0.004 sq. in. to 0.02 sq. in. @ 14 AWG to 4 AWG, 79.7 lbf.in. @ 0.04 sq. in. to 0.1 sq. in. @ 3 AWG to 3/0 AWG |
| Trip Type | Thermal Magnetic |
| Trip Unit Technology | Thermal-Magnetic |
| Utilisation Category | Category A |
| Voltage | 600V |
| Voltage Type | AC |
| Width | 3.19" |
| standard | CSA C22.2 NO 5, EN/IEC 60947-2, EN/IEC 60947-5-1, GB 14048.2, NEMA AB1, NMX J-266, UL 489 |
| Height (cm) | 13.69 |
|---|---|
| Length (cm) | 8 |
| Width (cm) | 8.1 |
| Country Of Origin | MX |
|---|---|
| Weight (kg) | 1.3275 |