EATON HKDDC Series DC Circuit Breakers

Eaton HKDDC Series DC circuit breakers are ideal for protecting DC power distribution systems in a wide range of applications, such as data centres, renewable energy systems, telecommunication and industrial control systems.

Filter
StyleModelPrice (inc. GST)
A
HKDDC3225W
- SGD 21,627.14
RFQ
B
HKDDC3400KW
- SGD 21,204.99
RFQ
C
HKDDC3300A13S42
- SGD 28,761.12
RFQ
D
HKDDC3300WF01
- SGD 26,720.83
RFQ
C
HKDDC3400S4201
- SGD 26,537.90
RFQ
C
HKDDC3400A13T1001
- SGD 29,703.87
RFQ
C
HKDDC3400
- SGD 24,131.75
RFQ
D
HKDDC3350WF01
- SGD 26,720.83
RFQ
B
HKDDC3400WF01
- SGD 26,720.83
RFQ
A
HKDDC3100WF01
- SGD 25,446.00
RFQ
C
HKDDC3250
--
RFQ
C
HKDDC3250W
- SGD 21,627.14
RFQ
C
HKDDC3300A13T1001
- SGD 29,703.87
RFQ
A
HKDDC3200WF01
- SGD 26,720.83
RFQ
D
HKDDC3250WF01
- SGD 26,720.83
RFQ
A
HKDDC3150WF01
- SGD 28,057.57
RFQ
A
HKDDC3225WF01
- SGD 26,720.83
RFQ
B
HKDDC3400WA02T26
- SGD 28,578.21
RFQ

Features

  • Eaton HKDDC Series DC circuit breakers have a K frame for resisting harsh operating conditions and long service life.
  • They have current ratings ranging from 100 to 400A.
  • These DC circuit breakers are equipped with a non-interchangeable thermal-magnetic trip for enhanced safety & coordination by preventing the installation of trip units with incorrect ratings.

Standards and Approvals

  • UL 489

Frequently Asked Questions

How often should Eaton HKDDC Series DC circuit breakers be inspected and maintained?

To prevent safety hazards and ensure proper functioning, regular inspections and maintenance of Eaton HKDDC Series DC circuit breakers are essential. The frequency of maintenance required will vary based on the particular usage conditions and application, but it is generally advised to carry out routine inspections at least once per year.

What type of maintenance is required for Eaton HKDDC Series DC circuit breakers?

The maintenance of these DC circuit breakers includes cleaning and inspecting the breaker, replacing any worn or damaged parts and checking that the breaker still operates within its specified parameters. Depending on the particular usage, more extensive maintenance, like overhauling the breaker or swapping out the trip unit, may be needed periodically.

What should be checked during routine inspections of Eaton HKDDC Series DC circuit breakers?

  • Inspect the breaker visually to detect any indications of wear or damage.
  • Examine all connections thoroughly to ensure they are tight and secure.
  • Confirm the trip unit's calibration and make adjustments as needed.
  • Test any additional components, such as shunt trips or alarms to verify their functionality.
  • Verify that the breaker can trip and cut off the circuit in case of a fault.
  • Measure the insulation resistance of the breaker and search for any evidence of degradation or contamination.